Back to Top

1
Hi, Guest!

TIC20-W Factory Configured Indicator

Update Terakhir
:
07 / 12 / 2019
Min. Pembelian
:
0

Harga

CALL
We have a long experience in electrical switchgear and control gear such as Low and Medium-Voltage Switchgear (up to 24 kV), Control Relay Panel, and Low Voltage Distribution and Lighting Panels also we supplies of superior quality materials such as panels ,air-conditioning & refrigeration system equipment, compressors, etc

Detail TIC20-W Factory Configured Indicator

TIC20-W Factory Configured Indicator The LogTag® TIC20-W is an irreversible electronic temperature indicator used to monitor temperature in pharmaceutical transport applications of up to 20 days duration. PQS specific models: WHO Type 1 WHO Type 2 WHO Type Prevenar WHO Type RotaTeq® Statistical data can be viewed directly on the device or downloaded using a dedicated LogTag® Interface Cradle and freely available LogTag® Analyzer software. Models TIC20-W Operating Temperature Range -30° C ~ + 60° C ( -22° F ~ + 140° F) Ambient humidity range during transport & use 0% to 95% RH Resolution 0.1° C or better in range of -30° C to + 60° C ( 0.2° F to -22° F, 1° F from 100° F to 140° F) Accuracy Better than ± 0.5° C for -10° C to + 40° C ( + 14° F to + 104° F) Better than ± 1.0° C for -30° C to -10° C ( -22° F to + 14° F) Better than ± 1.0° C for + 40° C to + 60° C ( + 104° F to + 140° F) Sensor Reaction Time T90 less than 7 minutes by method detailed in EN12830: 199 Capacity Minimum & maximum temperature for each of the 20 days. 1st activation of each alarm for each day including trigger time and duration of each excursion. Please note the TIC20 does not store each individual temperature reading taken. Sampling Frequency Factory set to 60 minutes Memory type Non volatile Recordings 20 day statistics, temperature/ time excursions and alarm trigger time and duration for each day. Start delay Factory set to 60 minutes Sensor Precision electronic thermistor Vibration Withstands vibration specification as detailed in EN12830: 19 Shock Withstands shock specification as detailed in EN12830: 1999. Withstand 5 drops 1m to smooth concrete floor without loss of function or calibration. Environmental IEC 60529: IP64 Resistance to Electrical Storms Designed to resist the effects of intense electrical storms Power source 3V Lithium-Manganese Dioxide, non-replaceable Battery life Minimum storage life of 18 months before ‘ start’ . Monitoring period: 20 days. Minimum accessibility ( display) period of 6 months after ‘ stopped’ Size 73mm( W) x 34.0mm( H) x 8.6mm( T) Weight 30g Case Material Polycarbonate Warranty One year replacement warranty against defects in materials and workmanship from the date of purchase. Excludes misuse or abuse of the product or as a result of unauthorized alteration or repairs Calibration Certificate of Traceability and Calibration to ISO/ IEC17025 available on request. Alarm Events Single alarm event when recording temperatures lower than -0.5º C for 60 minutes or longer. TIC20-W1 WHO Type 1 alarm configuration for freeze sensitive vaccines: DTP, DT TT, Td HepB, IPV, HPV Liquid Hib and combination vaccines Pneumo ( other than Prevenar) TIC20-W2 WHO Type 2 alarm configuration suitable for the international shipment of: BCG, lyophilized Hib, OPV Measles, MR, MMR, Rabies Meningitis ( polysaccharide) Yellow fever vaccines Rotavirus ( other than rotateq) TIC20-WP WHO Type Prevenar alarm configuration for: Prevenar 7 Prevenar 13 TIC20-WR WHO Type RotaTeq® alarm configuration suitable for the international shipment of: RotaTeq®
Tampilkan Lebih Banyak
Kontak Kami